  STFD AVR
  Cater Replacement
  Mecc Alte Replacement
  Marathon Replacement
  Marelli Replacement
  General AVR
  Brush AVR
  Kutai/Basler Replacement
  charger
  Governor
  Deep Sea Controller Replacement
  Generator Other Parts
  Siemens Generator Series
  Solenoid
 
 
View
Name:

AMF25

Features

InteliLite iL-CU AMF25 is a comprehensive AMF-controller for single generating sets operating in stand-by mode. IL-CU AMF 25 features extended support of electronic engines.
InteliLite controllers are equipped with a powerful graphic display showing icons,
symbols and bar-graphs for intuitive operation, which sets, together with high functionality, new standards in Gen-set controls.
InteliLite automatically starts the Gen-set, closes the Gen-set C.B. when all
conditions are met, then stops the engine on external signal or by pressing push buttons.
InteliLite provides gas engine support without ventilation.
The key feature of InteliLite is its easy-to-use operation and
installation.Predefined configurations for typical applications are available as well as user-defined configurations for special applications.
The remote announciator iGL-RA15 can be connected to the AMF25 unit via CAN bus. Any
of the binary outputs can be configured (using LiteEdit software) to each LED diode on the RA15. The module can be also enabled or disabled using LiteEdit software.
iG-IOM and iGS-PTM modules are I/O extension modules equipped with 8 binary inputs, 8
binary outputs, 4 analogue inputs and one analogue output. The module can be used for AMF25 only.
•  Binary inputs and outputs are configurable the same way like inputs and outputs on
iL.
•  Analogue inputs are configurable like iL with the limitation that the binary and
tristate mode can not be used on PTM module.
•  The protection of analogue IOM/PTM inputs is activated by overcrossing the limits,
active only when the engine is running.
•  iG-IOM analogue inputs are resistive (the same parameters like iL)  0 Ω-2.4 kΩ.
The module IOM is designed for especially VDO resistive sensors.
•  iGS-PTM analogue inputs are configurable by jumpers to ranges 0-250Ω, 0-100mV, 0
-20mA.The module can be used especially for Pt100 sensors and current sensors. The module PTM is not suitable for VDO temperature sensor.
IL-CU Terminals:
IL-CU Terminals
Hint:
EXTENSION MODULE and TEST PORT serves for Extension IGS-PTM or IG-IOM and IGL-RA15
CAN bus connection only. This port is used for production tests as well.
AMF-Wiring Diagram:
AMF-Wiring Diagram
Hint:
MCB and GCB is recommended to be mechanically interlocked.
From IL-2.1 it is possible to start Volvo and Scania engines via CAN bus.

Technical parameters

POWER SUPPLY
Voltage supply:8-36V DC
Consumption:0.5-0.1A depend on supply voltage
Allowed supply voltage drop-out:50ms from min. 10V,return to min. 8V (valid for
InteliLite of hardware version 3.2 and higher)
Battery voltage measurement tolerance:2 % at 24V
Hint: For the supply voltage less than 7V the backlight of the display is switched
off.

OPERATING CONDITIONS
Operating temperature IL-CU:-20 to +70°C
Operating temperature IL-CU-LT#:-30 to +70°C
Storage temperature:-30 to +80°C
Protection front panel:IP65
Humidity:95% without condensation
STANDARD CONFORMITY
Low Voltage Directive:EN 61010-1:95 +A1:97
Electromagnetic Compatibility:EN 50081-1:94,EN 50081-2:96,EN 50082-1:99,EN 50082-2:97
Vibration:5 - 25 Hz, ±1.6mm, 25 - 100 Hz,  a = 4 g
Shocks:a = 200 m/s²

LOW TEMPERATURE MODIFICATION
LCD display limits controller operating temperature range to –20 °C to + 70 °C
even if the other electronic components work in wider temperature range.
Internal preheating foil is mounted in InteliLite LT to extend display operational
temperature range.
Preheating starts at temperature below 5 °C and preheating power depends on
temperature and power supply voltage.

TECHNICAL DATA
Operating temperature:-20°C to +70°C(IL-CU  Standard); -30°C to +70°C(Order
code:IL-CU-LT)
Storage temperature:-30°C to +80°C(IL-CU  Standard); -30°C to +80°C(Order
code:IL-CU-LT)
Preheating foil increases controller current consumption
No preheating:360mA(12VDC);230mA(24VDC);100mA(36VDC)
Preheating at ambient temperature(0°C):+50mA(12VDC);+25mA(24VDC);+20mA(36VDC)
Preheating at ambient temperature(-15°C):+180mA(12VDC);+85mA(24VDC);+150mA(36VDC)
Preheating at ambient temperature(-30°C):+20mA(12VDC);+65mA(24VDC);+100mA(36VDC)
InteliLite LT works immediately after switch on at -30°C and display becomes visible
after a few minutes.
Short-term voltage drops (e.g. during the engine cranking) do not affect the
operation at all.

DIMENSIONS AND WEIGHT
Dimensions:180x120x55mm
Weight:800g

MAINS AND GENERATOR
Nominal frequency:50-60Hz
Frequency measurement tolerance:0.1Hz

CURRENT INPUTS
Nominal input current (from CT):5 A
Load (CT output impedance):< 0.1 Ω
CT input burden:< 0.2 VA per phase (In=5A)
Max. measured  current from CT:10 A
Current  measurement tolerance:2% from the Nominal current
Max. peak current from CT:150 A / 1s
Max. continuous current:12 A

VOLTAGE INPUTS
Measuring voltage:231VAC  phase to neutral;400VAC  phase to phase
Maximal measured voltage:290VAC  phase to neutral
Input resistance:0.6 MΩ   phase to phase;0.3 MΩ   phase to neutral
Voltage measurement tolerance:2 % from the Nominal voltage
Overvoltage class:III (EN61010)

BINARY INPUTS
Number of inputs:7
Input resistance:4.7 kΩ
Input range:0-36 VDC
Switching voltage level for close contact indication:0-2 V
Max voltage level for open contact indication:8-36 V

CONTACT RELAY OUTPUTS
Number of outputs:2
Electric life cycle:min 100.000 switching cycles
Maximum current:12 A DC resistive load;4 A DC inductive load
Maximum switching voltage:36 VDC
Minimum load:24 V / 0.1 A
Insulation voltage:500 Veff

BINARY OPEN COLLECTOR OUTPUTS
Number of outputs:5
Maximum current:0.5 A
Maximum switching voltage:36 VDC

ANALOG INPUTS
Not electrically separated
Resolution:10 bits
Sensor resistance range:0 Ω-2.4 kΩ
Resistance measurement tolerance: 4 % ± 2 Ω out of measured value

SPEED PICK-UP INPUT
Type of sensor:magnetic pick-up (connection by shielded cable is recommended)
Minimum input voltage:2 Vpk-pk (from 4 Hz to 4 kHz)
Maximum input voltage:50 Veff
Minimum measured frequency:4 Hz
Maximum measured frequency:10 kHz (min. input voltage 6Vpk-pk)
Frequency measurement tolerance:1.5 %

*CAN BUS INTERFACE
Galvanically separated
Maximal CAN bus length:200m
Speed:250kBd
Nominal impedance:120Ω
Cable type:twisted pair (shielded)
Following dynamic cable parameters are important especially for maximal 200meters 
CAN bus length and 32 iS-COM units connected:
Nominal Velocity of Propagation:min. 75%  (max. 4.4 ns/m)
Wire crosscut:min.0.25 mm²
Maximal attenuation (at 1 MHz):2 dB / 100m